Open today · Monday to Sunday, 7:00 am to 9:00 pm 7 days a week, 7am to 9pm

Well and septic, one crew, free estimates Call (904) 222-7465

CallFlamingoWell & Septic
A water well drilling rig at work on a rural lot outside Jacksonville, Florida

HomeWell servicesPressure Tank Replacement

Short cycling, surging pressure

Pressure tank replacement before the pump pays for it

A waterlogged tank makes a healthy pump start every few seconds. The charge is checked, the switch is set to it, and the tank is replaced where the bladder has failed.

Monday to Sunday, 7:00 am to 9:00 pm · free estimates · over 20 years of local experience

At a glance

Symptom
Rapid clicking, swinging gauge, surging shower
Checked
Air charge with the pump off and tank drained
Sized to
The pump's flow rate and minimum run time

The cheapest well fault to fix and the dearest to ignore

A pressure tank holds a cushion of air over the water so the pump can rest between draws. When the bladder fails or the air charge leaks away, the tank is full of water with nowhere for it to compress, so the pump starts every time a glass is filled. That is short cycling, and it is how good pumps die young.

The symptom is unmistakable once you know it: rapid clicking at the switch, the gauge needle swinging, pressure that surges and drops in the shower. A knuckle on the tank tells the story too: a healthy tank rings hollow at the top and thuds at the bottom; a waterlogged one thuds all the way up.

Call Flamingo checks the air charge with the pump off and the tank drained, sets it to match the switch, and replaces the tank where the bladder has gone.

Replaced at the same visit

Pressure switch and gauge

  • Cut-in and cut-out settings checked against the tank pre-charge
  • Pitted or burnt contacts replaced before they weld shut
  • A gauge that reads wrong replaced so the system can be trusted
  • The nipple between tank and switch cleared of the scale that blocks it

Straight answers

Questions this job raises

How do you know the tank is waterlogged?

Rapid on-off cycling at the switch, a gauge that swings, and a tank that thuds instead of ringing when tapped near the top. Confirmed by checking the air charge with the tank drained.

Can the air charge just be topped up?

If the bladder is intact, yes, and that is the first thing tried. If the charge will not hold, the bladder has failed and the tank is replaced.

Does the pressure switch need replacing with the tank?

Not always, but it is checked. A switch that has been cycling thousands of times a week has usually pitted its contacts.

Free estimate, then the work

Call Flamingo quotes well work at no charge and schedules seven days a week across the Jacksonville area.

Call (904) 222-7465Request a quote

7 days a week, 7am to 9pm

Call (904) 222-7465 Free estimate